Wiki Page: W97-99: No analyzed pressure cases present. Only axial GR stress is added message appears in AutoPIPE, why?

$
0
0
Applies To Product(s): AutoPIPE Version(s): 2004, XM, V8i Environment: N/A Area: Subarea: Original Author: Bentley Technical Support Group Date Logged & Current Version Oct. 2015 09.06.02.06 Problem: The following message appears in AutoPIPE: --------------------------- Warning --------------------------- W97-99: No analyzed pressure cases present. Only axial GR stress is added. --------------------------- OK --------------------------- Why and how to avoid it? Answer: As the message indicates that the analysis set(s) does not have an active pressure case. Avoidance: Select one of the following options: a. Turn OFF the following setting: Tools> Model Options> Results> Include Axial, Pcase in Sustained or b. If "Include Axial, Pcase in Sustained" is enabled, then for at least one Static Analysis Set enable the following feature: " Pressure Ext. " also known as "Calculate pressure extension cases, e.g. P1, P2, etc". This feature is located under Load> Static Analysis Set> . See Also Bentley AutoPIPE External Links Bentley Technical Support KnowledgeBase Bentley LEARN Server Comments or Corrections? Bentley's Technical Support Group requests that you please submit any comments you have on this Wiki article to the "Comments" area below. THANK YOU!