Applies To Product(s): AutoPIPE Version(s): 2004, XM, V8i Environment: N/A Area: Calculation Subarea: Original Author: Bentley Technical Support Group Date Logged & Current Version Oct. 2015 09.06.02.06 Problem: AutoPIPE calculates a SNiP hoop allowable of 178.39 N/mm2 in the output report, but 0.0 N/mm2 in the results grid, why? Answer: In result grid Hoop allowable is calculated only for "Plastic Strain" category. The results grid only prints the hoop allowable during plastic strain hoop stress check. It will never print a value for hoop allowable for the default combination Max P. See Also SNIP Piping Code Calculation Issues in AutoPIPE Bentley AutoPIPE External Links Bentley Technical Support KnowledgeBase Bentley LEARN Server Comments or Corrections? Bentley's Technical Support Group requests that you please submit any comments you have on this Wiki article to the "Comments" area below. THANK YOU!