Problem:
The following is displayed in the model consistency check report:
W726-93: Zero weight flange found at point XXX
How to fix?
Answer:
Open the offending flange dialog screen, or navigate to the Input grid, Flange tab:
Notice that the indicated flange weight is missing.
For all flange ratings = NS (Non-Standard) user must manually update the weight field.
Or
Select a different Flange Rating that will then retrieve the information from the flange library if available.