AutoPIPE Preview Handler error on installation Closed loop detected in imported model at TEE point XXX. E15-13: PXD file is needed for accessing AutoPLANT data in this model Please place PXD and PXH files in same directory as DAT file. E13-16: Cannot Find the specified units file E21-40: Executing this operation can corrupt distributed load records in AutoPIPE E38-95: Cannot insert component after a tee E90-21: Analysis results do not exist E102-155: This point must be an anchor/reference point E119-1: Maximum number of load combinations exeeded E131-30: AUTOPIPE.CLR not found E156-38: Value must be greater than zero E175-28: Error in velocity profile specification E221: Please contact Rebis E511-1: Invalid AutoPIPE data file E512-65: the model cannot be opened E512-109 cannot open Projectwise model E512-149: Model name must not contain space character before extension E514-2: Unable to retrieve Time History Load and Time History files E521-22: Base point is not on selected range E522-32: Cannot find clipboard file in current directory E522-33: Cannot complete the paste operation E723-23: System is not complete for analysis purposes E726-104: Zero length not allowed at beam XX E732-2: Angle is 180 deg. at bend xxx E732-3: Not enough clearance to fit bend xxx E737-26: Valve components are not permitted in HDPE pipe system as per CC N-755-1 E751-1 Tee type gt 8 or lt 1. SIF not calculated E774-44: Equation requires more combinations to be complete E801-1: FATAL ERROR: Unstable System E801-3: No static load cases specified E801-4: Zero length element E801-5: Zero Element Stiffness in AutoPIPE E801-11: Fatal Error: no mass in the system E801-12: Cannot find next frequency E801-24: Number of MSRS groups is inconsistent with SAM case - Error Message in AutoPIPE E801-75: Cannot allocate memory for analysis, unload some applications. E801-135: Number of analysis nodes exceeds maximum limit of 10000 nodes E829-1: Incorrect model size in file Static analysis results will be ignored. E951-3: Expecting real input. Re-enter Answer: insert a valid value into the current field before selecting a different cell / OK button. E962-1: File read error, please contact BENTLEY E962-2: File write error, check disk space E963-8: Non-ascii characters or "?" are not permitted in name E963-21: Number of characters in name cannot exceed 48 E2164-15: Qualified stress for all bend and tee components should be greater than zero Error 1316 - A network error occurred while attempting to read from the file No load case is selected to print time history results No Piping with OD >= 1.400 inches is found in PXF file "Root Element Is Missing" Time history analysis file (*.TIM) does not exist. Also See: Warnings, Errors, Crashed, Confirm Messages
↧