Quantcast
Channel: AutoPIPE
Viewing all articles
Browse latest Browse all 16073

Wiki Page: 11. AutoPIPE Stress Isometric customization - hide label "NS" from Pipe size

$
0
0
Applies To Product(s): AutoPIPE Version(s): CONNECT; Area: Stress Isometric Original Author: Bentley Technical Support Group Date Logged & Current Version Feb. 2016 10.00.00.10 Problem: How to hide label "NS" (Nominal Size) from being displayed on an AutoPIPE Stress Isometric using OPIM? Solution: Start by closing all AutoPIPE applications. The style.xml file requires an update. It is located in following folder: AutoPIPE 10.xx and higher: C:\ProgramData\ Bentley\ AutoPIPE CONNECT \ isoextractor\ projects\ project01\ stress\ Config AutoPIPE 09.06.xx and lower: “[InstallationDirectory]\isoextractor\projects\project01\stress\Config\style.xml”. The file can be open in any Text editing application (i.e. MS Word, NotePAD, UltraEdit ect..) After opening the file, search for the following entry: %NS Modify the entry to remove the "NS", but leave the % : % . Save the file, close the file, start AutoPIPE, open/create a model, save a Stress Isometric and confirm the setting works. See Also Customize AutoPIPE Stress Isometric drawings Bentley AutoPIPE