Wiki Page: "Bentley Systems, Inc" Messages displayed in AutoPIPE
Open plant isometric manager stopped working See Also Warnings, Errors, Crashed, Confirm Messages Bentley AutoPIPE
View ArticleWiki Page: "Open plant isometric manager stopped working" message appears...
Applies To Product(s): AutoPIPE Version(s): ALL; Area: Stress Isometric Date Logged & Current Version Feb. 2018 11.02.00.10 Problem: When trying to create a Stress isometric in AutoPIPE the...
View ArticleWiki Page: 22. How to remove "G" from support in a stress isometric created...
Applies To Product(s): AutoPIPE Version(s): ALL; Area: Stress Isometric Date Logged & Current Version Feb. 2018 11.02.00.10 Problem: How to remove "G" from support in a stress isometric created by...
View ArticleWiki Page: 02. Customize AutoPIPE Stress Isometric drawings
Following topics cover how to customize AutoPIPE's Stress Isometric to meet your company standards: Item 0: Quick Reference for OpenPlant Isometrics Manager Productivity Tools Modify Elements Tool...
View ArticleWiki Page: 22. Stress Isometric - Enhancements & Defects for AutoPIPE
Note: if an enhancement or defect has not been added to the program, log an Service request for that enhancement. The more requests logged per an enhancement, the quicker the CAE development team will...
View ArticleWiki Page: "EN 13480" Piping Code Enhancements & Defects for AutoPIPE
Note: if an enhancement or defect has not been added to the program, log an Service request for that enhancement. The more requests logged per an enhancement, the quicker the CAE development team will...
View ArticleForum Post: Pipe Properties Insulation Density
I have been trying to add insulation to my piping and I have a density value in lb/ft^3, but I can not assume the units because the other values that are preset in the program like glass and wool do...
View ArticleWiki Page: 01. How are the Stress Indices columns Z, ZBr, Zr, Zb calculated...
Applies To Product(s): AutoPIPE Version(s): ALL; Area: Results Date Logged & Current Version Oct. 2017 11.01.00.23 Problem: How are the Stress Indices columns Z, ZBr, Zr, Zb calculated in...
View ArticleWiki Page: 23. How to control elevation on stress isometrics using AutoPIPE?
Applies To Product(s): AutoPIPE Version(s): 11.02.00.10 Area: Stress isometric Date Logged & Current Version Feb. 2018 11.02.00.10 Problem: How to control elevation on stress isometrics using...
View ArticleWiki Page: "Alert" Messages displayed in AutoPIPE
Item #1: File [c:\User\...\drawing name] does not exist Also See Warnings, Errors, Crashed, Confirm Messages
View ArticleWiki Page: Microsoft Word Results Reports - AutoPIPE Technology Preview
Applies To Product(s): AutoPIPE Version(s): CONNECT Environment: N/A Area: Technology Preview Original Author: Bentley Technical Support Group Date Logged & Current Version March. 2017 11.00.00.22...
View ArticleForum Post: EXTERNAL NOZZLE LOAD (LOCAL LOAD) CALCULATIONS AS PER CODAP
Hi, CODAP 2010 Chapter C9.8 specifies a method for analyzing nozzles for external loads;yet AutoPIPE vessel doesn't provide an option to select CODAP as a local load design method. Kindly request you...
View ArticleWiki Page: 24. How to add a text label for "type of Tee" on a stress...
Applies To Product(s): AutoPIPE Version(s): 10.xx.xx to 11.02.00.10 Area: Stress isometric Date Logged & Current Version Feb. 2018 11.02.00.10 Problem: How to add a text label for "type of Tee" on...
View ArticleForum Post: Batch Model input listing & output report
Hello, I have about 150 stress systems that I'd like to create input listing reports and output reports for and would prefer not to have to open each file and create them manually. Is there a...
View ArticleForum Post: RE: Batch Model input listing & output report
Ok I found Batch File Generator and it works my purposes but when creating the reports I only want certain boxes tick'd (thermal anchor movements, load summary, etc). Is there a way to change the...
View ArticleForum Post: Input of Reducing valve?
Hello Everybody, I am trying to analyze a line which contains reducing valve with two ends having 100A and 200A size. I am confused about how to input the line. What should be the property of the line...
View ArticleWiki Page: AutoPIPE Vessel - Frequently Asked Questions
1. Fundamentals 2. General a. General FAQ's b. Entering Data into program c . Material Database and Default Libraries d. Nozzle, Flange Design e. Import / Export f. Menu Commands i. Execute ii. Insert...
View ArticleWiki Page: 11. AutoPIPE Stress Isometric customization - hide label "NS" from...
Applies To Product(s): AutoPIPE Version(s): CONNECT; Area: Stress Isometric Original Author: Bentley Technical Support Group Date Logged & Current Version Feb. 2016 10.00.00.10 Problem: How to hide...
View ArticleWiki Page: .h - "Bend" - Modeling Approaches in AutoPIPE
Overview:Comments, Questions, and Answers about modeling approaches for "Bends" Please see the following AutoPIPE help section: Help > Contents> Contents Tab> Modeling Approaches> Modeling...
View ArticleWiki Page: 07. How do I model a Fire hose valve?
Applies To Product(s): AutoPIPE Version(s): ALL; Area: Modeling Date Logged & Current Version Feb. 2018 11.02.00.10 Problem: How do I model a Fire hose valve? Solution: There are a few different...
View Article