Wiki Page: Download, Install, and License AutoPIPE V8i ATS 09.06.xx.xx and...
Applies To Product(s): AutoPIPE Version(s): 2004, XM, V8i Environment: N/A Area: Subarea: Original Author: Bentley Technical Support Group Date Logged & Current Version Dec 2014 09.06.01.10...
View ArticleWiki Page: Libraries - AutoPIPE
Applies To Product(s): AutoPIPE, Version(s): 2004, XM, & V8i Environment: N/A Area: Libraries Subarea: Original Author: Bentley Technical Support Group Comments, Questions, and Answers about...
View ArticleWiki Page: 01. is there a way to apply different temperature cases to part of...
Applies To Product(s): AutoPIPE Version(s): 2004, XM, V8i Environment: N/A Area: Settings Subarea: Original Author: Bentley Technical Support Group Date Logged & Current Version Feb. 2015...
View ArticleWiki Page: 02. What are the Units used when Selecting a specific Unit file...
Applies To Product(s): AutoPIPE Version(s): 2004, XM, V8i Environment: N/A Area: Settings Subarea: Original Author: Bentley Technical Support Group Date Logged & Current Version Feb. 2015...
View ArticleWiki Page: 02-01. General Model Options Dialog - AutoPIPE
Applies To Product(s): AutoPIPE, Version(s): 2004, XM, & V8i Environment: N/A Area: Subarea: Original Author: Bentley Technical Support Group Comments, Questions, and Answers about AutoPIPE's...
View ArticleForum Post: RE: Thermal expansion
Does anybody have information of how calculate Trans. Stiff/Rot. stiff, when selecting flexible anchor?
View ArticleForum Post: RE: Thermal expansion
If you have a structural model software like Staad or and FEA software like SolidWorks Simulation you can build an analysis model that will emulate your anchors and add a load to the anchor. Then you...
View ArticleForum Post: RE: Thermal expansion
So without that softwares I can't continue simulation in Autopipe?
View ArticleForum Post: RE: Thermal expansion
If you can provide a screen shot or photo of these anchors the community may be able to give you some insight on how to model these anchors within AutoPIPE to provide the stiffness values. Depending on...
View ArticleForum Post: RE: Thermal expansion
as I wrote before, this is the problem I have, a pipe exits a reactor by a nozzle and is connected to the suction of a pump by a flange, the temperature is 400°C, and the stress due to thermal load is...
View ArticleForum Post: RE: Thermal expansion
Hello Quique0185, If you have a nozzle on the side of a tank, you can insert an Nozzle element in AutoPIPE and specify some parameters for the application to calculate the stiffness related to the...
View ArticleWiki Page: RCC-M Piping Code Calculation Issues in AutoPIPE
Applies To Product(s): AutoPIPE Version(s): 2004, XM, V8i Environment: N/A Area: Subarea: Original Author: Bentley Technical Support Group Date Logged & Current Version Feb. 2015 09.06.01.10...
View ArticleWiki Page: Piping Code Calculations - AutoPIPE
Applies To Product(s): AutoPIPE, Version(s): 2004, XM, & V8i Environment: N/A Area: Subarea: Original Author: Bentley Technical Support Group Item #1, Comment: Be sure to review the following...
View ArticleWiki Page: What Piping codes are available in AutoPIPE Standard, Plus, or...
Applies To Product(s): AutoPIPE, Version(s): 2004, XM, & V8i Environment: N/A Area: general Subarea: Original Author: Bentley Technical Support Group Problem: What Piping codes are available in...
View ArticleWiki Page: How to update AutoPIPE with a new piping code or a new Code...
Applies To Product(s): AutoPIPE, Version(s): 2004, XM, & V8i Environment: N/A Area: Piping Codes Subarea: Original Author: Bentley Technical Support Group Problem: How to update AutoPIPE with a new...
View ArticleForum Post: RE: Thermal expansion
I also simulated the nozzle, but ultimately it is connected to a rigid vessel so at the end of the nozzle i have to fix a rigid anchor, which will give me the same result than the image above (i have...
View ArticleForum Post: RE: Thermal expansion
Hello Quique0185, That is correct you cannot take credit for tank stiffness with a nozzle element and then set an anchor to be flexible. The correct approach for modeling a nozzle on the side of a tank...
View ArticleWiki Page: W801-14: No frequency below cutoff value in AutoPIPE
Applies To Product(s): AutoPIPE Version(s): 2004, XM, V8i Environment: N/A Area: Warning Subarea: Original Author: Bentley Technical Support Group Date Logged & Current Version Feb. 2015...
View ArticleWiki Page: Warnings Messages displayed in AutoPIPE
Applies To Product(s): AutoPIPE, Version(s): 2004, XM, & V8i Environment: N/A Area: Warning Subarea: Original Author: Bentley Technical Support Group W21-38: This function cannot be applied at the...
View ArticleWiki Page: Crashed When Opening AutoPIPE Model, what can be done?
Applies To Product(s): AutoPIPE, Version(s): 2004, XM, & V8i Environment: N/A Area: Open Subarea: Original Author: Bentley Technical Support Group Problem: When opening a model in AutoPIPE the...
View Article