Wiki Page: AutoPIPE V8i Select Series 5 Release Notes (09.06.xx.xx)
Applies To Product(s): AutoPIPE, Version(s): 2004, XM, & V8i Environment: N/A Area: release notes Subarea: Original Author: Bentley Technical Support Group AutoPIPE V8i Select Series 5 Release...
View ArticleWiki Page: Bentley AutoPIPE V8i SELECTseries 5 (v09.06.00.15)
New Features In AutoPIPE V8i (SELECTseries 5) v09.06.00.15 Date Posted: 10/04/2013 08:44:47AM Platforms: Windows XP Windows Vista Windows Vista x64 Windows XP x64 Windows 7 Windows 7 x64 Languages:...
View ArticleWiki Page: 01. My AutoPIPE results does not appear to be considering weight...
Applies To Product(s): AutoPIPE Version(s): 2004, XM, V8i Environment: N/A Area: Subarea: Original Author: Bentley Technical Support Group Date Logged & Current Version Feb. 2015 09.06.01.10...
View ArticleWiki Page: 03. Is it possible to export / store / import AutoPIPE Static...
Applies To Product(s): AutoPIPE Version(s): V8i Environment: N/A Area: Subarea: Original Author: Bentley Technical Support Group Date Logged & Current Version Feb. 2015 09.06.01.10 Problem: Is it...
View ArticleForum Post: B31.4 Allowable Expansion Stress
In reviewing the analysis results for a model I have been working on, I found an inconsistency which I would appreciate assistance in resolving. The allowable expansion stress decreased when I changed...
View ArticleWiki Page: 04. I wish to run a thermal-only analysis load case in an Static...
Applies To Product(s): AutoPIPE Version(s): 2004, XM, V8i Environment: N/A Area: Subarea: Original Author: Bentley Technical Support Group Date Logged & Current Version Feb. 2015 09.06.01.10...
View ArticleWiki Page: 02b. Static Analysis Sets in AutoPIPE
Applies To Product(s): AutoPIPE, Version(s): 2004, XM, & V8i Environment: N/A Area: Analysis Subarea: Original Author: Bentley Technical Support Group The Load> Static Analysis Sets command...
View ArticleWiki Page: 02. Static / Dynamic Analysis Fluid Density Factor
Applies To Product(s): AutoPIPE, Version(s): 2004, XM, & V8i Environment: N/A Area: Analysis Subarea: Original Author: Bentley Technical Support Group As a new feature in AutoPIPE V8i 09.06.xx.xx...
View ArticleForum Post: AutoPIPE Vessel in Hosted server (selectserver.bentley.com)
Dear Bentley Team, In behalf of your loyal client Chiyoda Philippines Corporation, we want to raise this item all about AutoPIPE Vessel. We have migrated our licensing from deployed to hosted yet our...
View ArticleBlog Post: Featured LEARNing: AutoPIPE virtual classes on March 3-6, 2015
AutoPIPE Nuclear Powered by ADLPipe Mar. 03-04, 2015: 8:00 AM - 12:00 PM EST (8 hrs) Phil Senior In this course, you will apply the features of AutoPIPE Nuclear powered by ADLPipe to model safety...
View ArticleForum Post: RE: Revising Weld EFF. Factor
Hello P_Pipe, There is not enough information to reproduce this issue (i.e.. AutoPIPE version, Piping code (edition), exactly what factor (i.e. Tools> Model Option> Results> Weld efficiency...
View ArticleForum Post: RE: Difference between 'Hot modulus' option and 'Apply modulus...
Hello HVN, They are different as you had mentioned, this information is covered in AutoPIPE's online help: Apply modulus ratio - This option allows the Ec/Eh ratio to be applied to the moments used in...
View ArticleForum Post: RE: B31.4 Allowable Expansion Stress
Hello Geoffery, Your issue is being reviewed by the CAE development team. Regards, Mike Dattilio Bentley TSG Support Analyst ===================================================
View ArticleForum Post: RE: Resultant Forces in Axially Rotated Model
Hello Greg, I believe you are not aware of the following setting for AutoPIPE 09.06.01.xx and lower: Tools> model options> Results> "Force (Global/Local)" See AutoPIPE help for complete...
View ArticleForum Post: RE: Resultant Forces in Axially Rotated Model
This works for the forces and moments data - I'm aware of this - but my issue is in regards to determining support outputs. Is there a similar method for this? For instance if I look at the same node...
View ArticleForum Post: Major Release – AutoPIPE Vessel V8i (SELECTseries 1) Powered by...
Major Release – AutoPIPE Vessel V8i (SELECTseries 1) Powered by Microprotol (Version 33.3.0.20) is now Available. The Most Comprehensive Software for Vessel Pressure, Heat Exchanger, and Tank Design...
View ArticleForum Post: RE: Resultant Forces in Axially Rotated Model
Hello Greg, Using a test model in AutoPIPE V8i 09.06.01.11, based on a single load case, at a support location, I was able to get the same results. Please remember that the Support sub-report has 3...
View ArticleWiki Page: Import and Export - AutoPIPE
Applies To Product(s): AutoPIPE, Version(s): 2004, XM, & V8i Environment: N/A Area: Import / Export Subarea: Original Author: Bentley Technical Support Group Comments, Questions, and Answers on...
View ArticleWiki Page: 03-c: Export AutoPLANT (PXF) - Geometry/Results from AutoPIPE
Applies To Product(s): AutoPIPE Version(s): 2004, XM, V8i Environment: N/A Area: Subarea: Original Author: Bentley Technical Support Group Date Logged & Current Version Feb. 2015 09.06.01.10...
View ArticleWiki Page: AutoPIPE Vessel V8i V.33.03.00.20 Software Release Notes
The following Release Notes are provided as a reference by Bentley's Technical Support Group. Version Number: 33.03.00.20 Date Posted: 2/19/2015 2:58:00 PM Application Group: SELECT Released Products...
View Article