Wiki Page: Dynamic Analysis in AutoPIPE
Applies To Product(s):AutoPIPE,Version(s):2004, XM, & V8iEnvironment: N/AArea: AnalyzeSubarea: Original Author:Bentley Technical Support GroupDynamic Analysis FAQ:ModalResponse SpectrumHarmonicTime...
View ArticleWiki Page: •"Non-Code Comb." tab questions
Applies To Product(s):AutoPIPE,Version(s):2004, XM, & V8iEnvironment: N/AArea: combinationsSubarea: Original Author:Bentley Technical Support GroupComments, Questions, and Answers about No-code...
View ArticleWiki Page: Combination Load Cases (Tools Combinations dialog)
Applies To Product(s):AutoPIPE,Version(s):2004, XM, & V8iEnvironment: N/AArea: Load CasesSubarea: Original Author:Bentley Technical Support Group Load Combinations To review, modify or print new...
View ArticleWiki Page: Model Different Types of PIPING in AutoPIPE
Applies To Product(s):AutoPIPE,Version(s):2004, XM, & V8iEnvironment: N/AArea: ModelingSubarea: Original Author:Bentley Technical Support GroupProblem:What are some typical modeling approaches for...
View ArticleWiki Page: Modeling Approaches, Tips, Technique for Nozzle Piping Components...
Applies To Product(s):AutoPIPE,Version(s):2004, XM, & V8iEnvironment: N/AArea: ModelingSubarea: Original Author:Bentley Technical Support GroupAttention: Please see the following AutoPIPE help...
View ArticleForum Post: Nozzle modeling: W41-27 error
I am trying to model a 20" STD connection to a tank of 40 m diameter at 1 m above ground level, filled to 13 m high. Naturally I use the API 650 flexibility method (I assume it's using the Appendix P...
View ArticleWiki Page: AutoPIPE Warnings
Topics under the heading should be based on Warnings found in AutoPIPE:W31-86: No allowable stresses are available for the selected material in the material libraryW726-2: Gap orientation has...
View ArticleWiki Page: W31-86: No allowable stresses are available for the selected...
Applies To Product(s):AutoPIPE,Version(s):2004, XM, & V8iEnvironment: N/AArea: warningSubarea: Original Author:Bentley Technical Support GroupProblem:The following appears when I select a material...
View ArticleWiki Page: Import Enhancements for AutoPIPE
Applies To Product(s):AutoPIPE,Version(s):2004, XM, & V8iEnvironment: EnhancementsArea: Subarea: Original Author:Bentley Technical Support GroupThe following imported enhancements have been logged...
View ArticleWiki Page: W801-121: V-stop liftoff(s) have occurred under operating
Applies To Product(s):AutoPIPE,Version(s):2004, XM, & V8iEnvironment: N/AArea: warningSubarea: Original Author:Bentley Technical Support GroupProblem:The following occurs when I run an...
View ArticleWiki Page: Reports - AutoPIPE
Applies To Product(s):AutoPIPE,Version(s):2004, XM, & V8iEnvironment: N/AArea: reportsSubarea: Original Author:Bentley Technical Support GroupComments, Questions, and Answers on AutoPIPE output...
View ArticleWiki Page: Dynamic Support Forces
Applies To Product(s):AutoPIPE,Version(s):2004, XM, & V8iEnvironment: N/AArea: resultsSubarea: Original Author:Bentley Technical Support GroupComments, Questions, and Answers about dynamic support...
View ArticleWiki Page: PCF Translator FAQ & troubleshooting - AutoPIPE
Applies To Product(s):AutoPIPE,Version(s):2004, XM, & V8iEnvironment: N/AArea: importSubarea: Original Author:Bentley Technical Support GroupComments, Questions, and Answers with PCF translator...
View ArticleWiki Page: W41-27: Parameters are outside the applicable range
Applies To Product(s):AutoPIPEVersion(s):V8iEnvironment: N/AArea: ModelingSubarea: Original Author:Darius Rimasauskas, Bentley Technical Support GroupError or Warning MessageThe following warning...
View ArticleForum Post: + & - Node
Can somebody remind me the meaning of + and - Node points that AutoPipe shows stresses for the same physical node point.cheers
View ArticleForum Post: Initial operational load case - output report
Dear all,Where can I get from output report meaning of initial operational load case I have defined before (see screenshot)?
View ArticleForum Post: Re: Equation (1b) clause 302.3.5 (ASME B31.3)
I received a comment from the client «This liberal equation shall not be used. This feature shall be turned off in the software».
View ArticleForum Post: Re: B31.1 Seismic Analysis In Autopipe
Аs ASME 31E said, I can use two variants for choosing seismic load direction: one is three directional excitations such as plant east-west, north-south and vertical, with the combination of...
View Article