Forum Post: How to separate the analysis set in AutoPipe file?
For example: separate to 2 part: one includes OP1 case and Hydrotest case, the other includes only OP1 Please refer to the image for more detail Red marked zone is for OP1 and Hydrotest case, not red...
View ArticleWiki Page: 02. What options are available to enter a new user defined...
Applies To Product(s): AutoPIPE Version(s): ALL; Environment: N/A Area: Library Original Author: Bentley Technical Support Group Date Logged & Current Version Oct. 2016 10.01.00.09 Problem: If a...
View ArticleWiki Page: 01b. Does AutoPIPE have my material?
Applies To Product(s): AutoPIPE Version(s): ALL; Area: Library Original Author: Bentley Technical Support Group Date Logged & Current Version Oct. 2016 10.01.00.09 Problem: Does AutoPIPE have my...
View ArticleForum Post: Mesh Refinement
Hi, Sorry if this has been answered. I am trying to figure out if there is a way to globally refine the mesh in AutoPIPE in static analyses without adding more points. My understanding is no as...
View ArticleForum Post: SIG Virtual Workshop: AutoPIPE - Learn What's New in AutoPIPE...
SIG Workshop: AutoPIPE - Learn What's New in AutoPIPE Version 12.4 Presenter: Jessica Alegre, Senior Mechanical Application Engineer, Bentley Systems Date: Thursday, September 10, 2020 at 1:00 pm EDT...
View ArticleWiki Page: E732-2: Angle is 180 deg. at bend xxx message in AutoPIPE
Applies To Product(s): AutoPIPE, Version(s): ALL Environment: N/A Area: error Original Author: Bentley Technical Support Group Problem: The following is displayed when I am inserting a bend in my...
View ArticleForum Post: RE: Mesh Refinement
https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/25126/interm-stress-points-setting-in-autopipe
View ArticleWiki Page: E732-1: Angle is 0 deg. at bend xxx message in AutoPIPE
Applies To Product(s): AutoPIPE Version(s): ALL Area: error Original Author: Bentley Technical Support Group Problem: The following is displayed when using the program: ---------------------------...
View ArticleWiki Page: "Error" messages displayed in AutoPIPE
AutoPIPE Preview Handler error on installation Closed loop detected in imported model at TEE point XXX. E15-13: PXD file is needed for accessing AutoPLANT data in this model Please place PXD and PXH...
View ArticleWiki Page: 37. Is the corrosion allowance taken into account for the tubes in...
As per the ASME code (and also other PV design codes) the nominal thickness of tubes is used in the tubesheet calculation (i.e. new, not corroded). See: UHX-11.3:
View ArticleWiki Page: Shell and Tube Heat Exchangers
01. When choosing a 8" nominal shell size the O.D. is reflected as 8.78" O.D. (it should be 8.625"). 02. How to import Aspentech edr file into AutoPIPE Vessel? 03. For a shell and tube exchanger with...
View ArticleWiki Page: 13. Why are spring or rigid hangers on vertical legs showing large...
Applies To Product(s): AutoPIPE Version(s): ALL; Area: Reporting Date Logged & Current Version Sept2020 12.04.00.13 Problem: Why are spring or rigid hangers on vertical legs showing large reaction...
View ArticleOutput Report in AutoPIPE">Wiki Page: "Support" sub report using Results> Output Report in AutoPIPE
Comments, Questions, and Answers for Support sub-report using Results> Output Report in AutoPIPE Item #1: Difference between the Support and Restraint output reports Item #2: Membrane stresses at...
View ArticleWiki Page: W801-14: No frequency below cutoff value in AutoPIPE
Applies To Product(s): AutoPIPE Version(s): 2004, XM, V8i Environment: N/A Area: Warning Original Author: Bentley Technical Support Group Date Logged & Current Version Feb. 2015 09.06.01.10...
View ArticleWiki Page: 01. Bentley AutoPIPE Automatic Test Set (ATS)
The Bentley AutoPIPE Acceptance Test Set (ATS) provides the user with a recommended procedure for validating the integrity of an installed AutoPIPE QA & Report subscription service version of the...
View ArticleWiki Page: License AutoPIPE - Outside of application
SES (Subscription Entitlement Service) AutoPIPE v.12.00 and higher Virtuosity - Why Virtuosity? SELECTserver AutoPIPE v.11.04 and lower FAQ's that apply to both categories above 1. Who are my company's...
View ArticleWiki Page: Q. I am not able to access this Software download website for...
Sorry, you do not have access to Software Downloads Application. or "Sorry, you do not have access to SELECT support services. Your account is not associated with a SELECT site entitlement." Answer:...
View ArticleWiki Page: 05c. Reinforcement Pad tab related questions - AutoPIPE Nozzle
tab image 1. What is ""Attenuate pad loads"" option in AP Nozzle? Answer : When it is enabled, flexibility of the pad or vessel is considered when calculating stresses. . See Also Table Of Contents...
View ArticleWiki Page: AutoPIPE CONNECT v.12.04.00.13 - Read Me file
What is New & Changed in AutoPIPE® AutoPIPE CONNECT Edition version 12.4 (v12.04.00.13:2020-07) The following outline identifies new features and enhancements in the AutoPIPE CONNECT Edition...
View ArticleWiki Page: 01a. AutoPIPE CONNECT Release Notes (10.00.xx.xx - higher)
AutoPIPE CONNECT Commercial Release Notes QA Release Notes v12.04.00.13 v12.03.00.17 v12.02.00.14 v12.01.00.10 v12.01.00.09 v12.00.00.14 v.11.04.00.10 v.11.03.00.08 v.11.02.00.10 v.11.02.00.08...
View Article