Quantcast
Channel: AutoPIPE
Viewing all articles
Browse latest Browse all 16073

Forum Post: RE: Static seismic and equivalent thermal expansion for buried pipes

$
0
0
Hi Mike, Thank you for your response. I just want to confrim. Autopipe does calculate "static seismic (earthquake)"  loads for aboveground and undeground pipes correctly using static seismic coefficient. The resulted displacements, forces, moments and stresses are properly calculated for all points (aboveground points and soil points). But "static seismic (earthquake)"  loads does not consider the "seismic wave propagation" effects and resulting axial strain to buried piping, due to wave passage. So if "seismic wave propagation" effects shall be considered then should be used "Seismic Thermal Load" case (for newer versions), or to hand calculate an equivalent thermal range and add it to operating temperature (for older versions)? Regards, Galin.

Viewing all articles
Browse latest Browse all 16073

Trending Articles



<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>