Forum Post: RE: Error 227 SUPPORT: yield stress at temperature missing (570˚C)

Hello Hayden, ASME Sec. II D, Table Y-1 lists yield stress values only upto temperature of 525 C, since the design T=570 C, hence the error message. I would be interested to know where did you obtain...

View Article


Forum Post: RE: Error 227 SUPPORT: yield stress at temperature missing (570˚C)

Also which version of the product are you using? Do you have the latest version 33.3.1.7?

View Article


Wiki Page: EN13480 Piping Code Calculation Issues

Applies To Product(s): AutoPIPE, Version(s): 2004, XM, & V8i Environment: N/A Area: Subarea: Original Author: Bentley Technical Support Group Comments, Questions, and Answers about EN 13480 Piping...

View Article

Wiki Page: PlantFLOW 06.01.xx.xx and lower - Trouble shooting licensing

Applies To Product(s): PlantFLOW Version(s): 06.01.xx.xx and Lower Environment: N/A Area: licensing Subarea: Original Author: Bentley Technical Support Group Problem: What typical licensing trouble...

View Article

Wiki Page: Download, Install, and License - PlantFLOW 06.02.xx.xx and higher

Applies To Product(s): Plantflow Version(s): 06.02.xx.xx and higher Environment: N/A Area: Download, Install, License Subarea: Original Author: Bentley Technical Support Group Note : Bentley PlantFLOW...

View Article


Forum Post: RE: Error 227 SUPPORT: yield stress at temperature missing (570˚C)

Thanks Sudip, That explains things. I'd tried a few other things and entering the stress at 1000 F (538 F) from the table was my last try. I entered a value thinking it would be close enough to what I...

View Article

Forum Post: RE: Error 227 SUPPORT: yield stress at temperature missing (570˚C)

I am currently running 33.3.0.20 so will update this too! Cheers

View Article

Wiki Page: "Execute" Menu Command in AutoPIPE Vessel

Applies To Product(s): AutoPIPE Vessel Version(s): V8i Environment: N/A Area: FAQ Subarea: Original Author: Bentley Technical Support Group Select a link below for FAQ's on that command: 1. Strength...

View Article


Forum Post: AutoPIPE instability with nozzles

Good Morning, I'm trying to calculate a column, but I can't finish toi complete the input because of the nozzles. Finished with filling of first windows, as needed, I try to get the page material but...

View Article


Wiki Page: PULS program stops working

Applies To Product(s): PULS, Version(s): all Environment: N/A Area: Program Crash Subarea: Original Author: Bentley Technical Support Group Comments, Questions, and Answers when PULS stops working:...

View Article

Forum Post: RE: AutoPIPE instability with nozzles

Hello Ettore, Questions like this are very difficult to resolve without reviewing the model and exact steps to repeat. Suggest that you log a Bentley Service request and add the following: a. AutoPIPE...

View Article

Forum Post: Modeling a pipeline resting on gravel

I have a 26" API-5L-B carbon steel pipeline around 1300 meters long running downhill at 10% slope and is resting on gravel the full length of the pipeline. What is the recommended way of modeling this...

View Article

Forum Post: RE: AutoPIPE instability with nozzles

Dear Mike, attached you’ll find the model. Follow the screen shot: The procedure is: 1. Insert new nozzle; 2. Fill the data needed in “Nozzle Neck”; 3. Fill the data in page “Standard Flange”; When...

View Article


Wiki Page: 01e. Model a LONG PipeLines with AutoPIPE

Applies To Product(s): AutoPIPE, Version(s): 2004, XM, & V8i Environment: N/A Area: Subarea: Original Author: Bentley Technical Support Group Dec 2014, AutoPIPE V8i 09.06.01.10 Problem: Can...

View Article

Forum Post: RE: Modeling a pipeline resting on gravel

Hello John, Your approach is ok, but who is to say what the friction of steel is on gravel. Also See the following WIKI here: Regards, Mike Dattilio Bentley Product Advantage Group Analyst...

View Article


Forum Post: RE: Take the Navigator CONNECT Test Drive

Hi, Can anyone know why I don't have the same syncronize button on my app as in the pdf manual ? Same true for the windows version. Thanks.

View Article

Wiki Page: 12. Soil Load Enhancements for AutoPIPE

Applies To Product(s): AutoPIPE, Version(s): 2004, XM, & V8i Environment: N/A Area: Enhancements Subarea: Original Author: Bentley Technical Support Group The following enhancements have already...

View Article


Wiki Page: 12. How can I model a pipe that is supported over all its length...

Applies To Product(s): AutoPIPE Version(s): 2004, XM, V8i Environment: N/A Area: Modeling Soil Subarea: Original Author: Bentley Technical Support Group Date Logged & Current Version July 2015...

View Article

Forum Post: RE: Microsoft Access (MDB file) use in AutoPIPE

I previously wrote a program to parse the MDBs for communicating loads to structural engineers. I don't think that this is being used anymore and that company reverted to manually transcribing...

View Article

Forum Post: Expansion Joint To Equipment - Pressure Thrust?

What is the most correct way to model an expansion joint on a piece of equipment to account for the pressure extension of the expansion joint while not reporting "extra" pressure thrust on the...

View Article