Forum Post: RE: Static seismic and equivalent thermal expansion for buried pipes
Mike, Thanks a lot. That's all I was interested. Regards, Galin.
View ArticleForum Post: RE: Time History Analysis
Hello Roger3, Per the information provide here and without looking at the model. I would venture to guess that the computer you are using is not suited to run the analysis with the current model...
View ArticleWiki Page: E801-135: Number of analysis nodes exceeds maximum limit of 10000...
Applies To Product(s): AutoPIPE, Version(s): 2004, XM, & V8i Environment: N/A Area: error Subarea: Original Author: Bentley Technical Support Group Problem: What is the node limit in AutoPIPE or...
View ArticleWiki Page: E801-12: Cannot find next frequency
Applies To Product(s): AutoPIPE, Version(s): 2004, XM, & V8i Environment: N/A Area: Subarea: Original Author: Bentley Technical Support Group Problem: When performing a modal analysis the...
View ArticleWiki Page: AutoPIPE Errors
Topics under the heading should be based on Error messages found in AutoPIPE: Application Error - 0xc0150002 E15-13: PXD file is needed for accessing AutoPLANT data in this model Please place...
View ArticleWiki Page: Modal Analysis - AutoPIPE
Applies To Product(s): AutoPIPE, Version(s): 2004, XM, & V8i Environment: N/A Area: Subarea: Original Author: Bentley Technical Support Group Comments, Questions, and Answers: Question #1:...
View ArticleWiki Page: Harmonic Analysis - AutoPIPE
Applies To Product(s): AutoPIPE, Version(s): 2004, XM, & V8i Environment: N/A Area: Analysis Subarea: Original Author: Bentley Technical Support Group Comments Questions and Answers about Harmonic...
View ArticleForum Post: RE: Question on Imposed Velocity Harmonic Analysis
Hello David Arnett, The devleopment team is asking that you send us your model for review. Please log a service ticket and attach your model APC file for review. Thanks for your time. Regards, Mike...
View ArticleFile: Creating a custom standard for saddle support
Creating a custom standard for saddle support
View ArticleForum Post: RE: Damper (snubber) with Slug flow
Hello JRW, I apologize for the inconvenience, however as stated in the online help for a Damper / snubber: Vibration dampers are active only for static seismic and dynamic load cases...
View ArticleForum Post: User defined SIF: Reference: {SrvReqNo:[7000113969]}
Hi, I have a question related to “USER-DEFINED SIFs” for Bends. Is it possible in AutoPipe to apply the user defined SIFs to only Bends (from A15N- to A15F+, in example below) without affecting...
View ArticleForum Post: RE: Damper (snubber) with Slug flow
Thank you for the reply. Is there any reason why snubber is not activated during User cases? Seems like it would make a lot of sense. And be a lot more convenient than setting up a time history. Is...
View ArticleWiki Page: Bentley AutoPIPE Vessel
Introducing AutoPIPE Vessel EXTON, Pa., U.S.A. - Oct. 15, 2013 - Bentley Systems, Incorporated, the leading company dedicated to providing comprehensive software solutions for sustaining...
View ArticleWiki Page: Bentley AutoPIPE Vessel - Vessel and Exchanger Support
1. Creating new saddle standard for horizontal vessels and heat exchangers.
View ArticleWiki Page: Dynamic Analysis in AutoPIPE
Applies To Product(s): AutoPIPE, Version(s): 2004, XM, & V8i Environment: N/A Area: Dynamic Analysis Subarea: Original Author: Bentley Technical Support Group Dynamic Analysis FAQ: Modal Response...
View ArticleWiki Page: Dynamic Support Forces
Applies To Product(s): AutoPIPE, Version(s): 2004, XM, & V8i Environment: N/A Area: results Subarea: Original Author: Bentley Technical Support Group Comments, Questions, and Answers about dynamic...
View ArticleForum Post: User SIF for complex geometries
Hi, Would you please advise methods (not the only one as I suppose there are more...) for user SIF values calculation, e.g. weldolets, non orthogonal tees, reducing tees etc. Users are requesting more...
View ArticleForum Post: RE: User SIF for complex geometries
EN 13480-3 app. H, issue 2, provides more examples, and I believe (even) more detailed calculations, for some very specific and complex geometries compared to B31.3:2012.
View ArticleForum Post: RE: Damper (snubber) with Slug flow
You can use static seismic E cases with zero acceleration and apply the slug static forces into these E cases. You do not need Time history, force spectrum or modal analysis for the E cases.
View ArticleWiki Page: Reports - AutoPIPE
Applies To Product(s): AutoPIPE, Version(s): 2004, XM, & V8i Environment: N/A Area: reports Subarea: Original Author: Bentley Technical Support Group Comments, Questions, and Answers on AutoPIPE...
View Article