Forum Post: RE: B31J SIFs
When you say yes, are you saying the rigid option and the additional SIF input at the OD of the header is no longer required for B31J? I asked two questions and I need more clarification. Thanks.
View ArticleForum Post: Forces/Moment vs Restraint Loads
Hi, I have modelled a pipe support using by connecting the support element to a rigid beam offset which is connected to a flexible anchor (see image). Note that the beam offset is not connected to the...
View ArticleForum Post: RE: Forces/Moment vs Restraint Loads
Greetings, Suggest to provide the Support sub report to the Civil team members. Then review how AutoPIPE calculates forces and moments by reviewing the following AutoPIPE help section: Help ribbon>...
View ArticleForum Post: RE: Local Displacements
There is a work around. You can add a guide support at the point of interest and set the support stiffness to zero. The support report will give you local displacements ( left, right. forward, back)
View ArticleForum Post: RE: Forces/Moment vs Restraint Loads
Thanks for the response, Mike! I read through the help section contents, but I guess I still don't quite understand how the calculated pipe "Forces and Moments" are converted to Restraint / Support...
View ArticleForum Post: RE: Forces/Moment vs Restraint Loads
Greetings, Please recall that the forces and moments reports are calculated forces and moments in the pipe. Meanwhile the support report is the bearing force of the pipe on the support per Linear /...
View ArticleForum Post: how to track displacements of reference points?
how to track displacements of reference points? I understand that reference points are only used to track forces and moments but i want to see separately the displacement results of these reference...
View ArticleForum Post: RE: how to track displacements of reference points?
Greetings, Unfortunately as of April 2024, this is not a feature in AutoPIPE. This is a good idea. Please use the instructions here to post your idea so it will be added to a future version of...
View ArticleWiki Page: AutoPIPE Wiki 日本語
AutoPIPE 日本語コミュニティへようこそ! このページではAutoPIPE関連製品に関する様々な技術情報を掲載しており、個人利用の方から商用利用の方まですべてのAutoPIPEユーザーがいつでもご覧頂ける情報サイトです。 はじめてAutoPIPE関連製品をご利用される方から熟練の方々まで自由に技術情報をご確認頂けます。 さらに必要な情報をこのWikiから探し出せなかった場合、質問を Forum...
View ArticleWiki Page: c. Technical Support - AutoPIPE
What is Bentley TSG? Bentley Technical Support Group (TSG) is dedicated to assisting our SELECT subscribers with technical problems encountered in Bentley applications. Technical problems include...
View ArticleWiki Page: 01. PCF Import process aborted or crashed: what should I do?
When importing an AutoPIPE NTL file from the PCF translator the following appears: --------------------------- Confirm --------------------------- Import process aborted. Review error messages :...
View ArticleWiki Page: E951-31: Cannot find or read autoplan.cnf file. Please reinstall...
Applies To Product(s): AutoPIPE, Version(s): All Area: Error Original Author: Bentley Technical Support Group Problem: The following appears when ever opening the program: ---------------------------...
View ArticleForum Post: SIF and Flexibility Factors for d/D
Hi, When using B31J, do SIFs and k factors get applied at the header pipe wall by default? And does it automatically model a rigid section from header centerline to pipe wall? Thanks, Sean
View ArticleForum Post: Autopipe traning
We are new in autopipe we need online training for our employs. kindly give the training.
View ArticleForum Post: RE: SIF and Flexibility Factors for d/D
Excellent question Sean. Ive always modelled tees with a short rigid section between centreline and the point where the branch (virtually) exits the header pipe. Looking forward to a reply from the...
View ArticleForum Post: RE: Autopipe traning
Greeting, Welcome to AutoPIPE, where you can use our modeling capabilities to simulate a multitude of scenarios. We are excited to introduce you to the diverse range of features that our software...
View ArticleForum Post: RE: SIF and Flexibility Factors for d/D
Hello Sean, thank you for your question. AutoPIPE performs SIF calculations based on the requirements of the figure you've enclosed - i.e. if the d/D Code Compliance Calculations> ASME B31J > Tee...
View ArticleWiki Page: .Bentley AutoPIPE
AutoPIPE is a CAE (Computer-Aided Engineering) program created to design and test piping systems in varying locations: nuclear and fossil power, process and chemical plants, offshore FPSO platform and...
View ArticleWiki Page: Error - How to resolve "Timeout Exceeded (3600 s)" error in...
Problem: How to resolve "Timeout Exceeded (3600 s)" error in AutoPIPE vessel? Why does this happen and how to avoid? Solution: Scenario #1: When user wants to perform the calculation, it is very...
View Article