Wiki Page: 03a. Add New Material to Existing Library, AutoPIPE V8i v.9.0 and...
Applies To Product(s): AutoPIPE, Version(s): 2004, XM, & V8i Environment: N/A Area: Library Subarea: Original Author: Bentley Technical Support Group Dec 2014, AutoPIPE V8i 09.06.01.10 Problem: How...
View ArticleWiki Page: 01. "*ERR* 10-07 bad character in input field" message is...
Applies To Product(s): AutoPIPE Version(s): 2004, XM, V8i Environment: N/A Area: Subarea: Original Author: Bentley Technical Support Group Date Logged & Current Version Aug. 2015 09.06.02.06...
View ArticleWiki Page: 10. Performing an AutoPIPE ANSI flange analysis, a specific flange...
Applies To Product(s): AutoPIPE Version(s): 2004, XM, V8i Environment: N/A Area: Subarea: Original Author: Bentley Technical Support Group Date Logged & Current Version Aug. 2015 09.06.02.06...
View ArticleForum Post: Maintenance Release 1 – AutoPIPE Vessel V8i (SELECTseries 1)...
Maintenance Release 1 – AutoPIPE Vessel V8i (SELECTseries 1) Powered by Microprotol (Version 33.3.01.07) - Chinese (Simplified) is now Available. The Most Comprehensive Software for Vessel Pressure,...
View ArticleForum Post: RE: How to add Nozzle Size in Isometric?
Hello Mike We are using AutoPLANT.
View ArticleForum Post: RE: How to find worst case of concentrated forces?
Thank you for suggesting a solution. However, it will take a while to implement as I have six forces (FX, FY, FZ, MX, MY, MZ) and need 2^6 = 64 load cases. I will make the best of it. Again, thanks for...
View ArticleForum Post: Integration of AutoPIPE and STAAD.Pro: Anchors
I am having some trouble with Anchor connections in AutoPIPE. First a simple model is created in AutoPIPE. This model consists of a guide and an anchor, both of which are supposed to be connected to...
View ArticleForum Post: RE: How to add Nozzle Size in Isometric?
Hello Sandip, please see the following WIKI communities.bentley.com/.../110135 Regards, Mike Dattilio Bentley Product Advantage Group Analyst ===================================================
View ArticleWiki Page: 03b. Modeling Vessel / Nozzles in AutoPIPE
Applies To Product(s): AutoPIPE, Version(s): 2004, XM, & V8i Environment: N/A Area: Modeling Subarea: Original Author: Bentley Technical Support Group The following section will contain questions...
View ArticleForum Post: RE: Integration of AutoPIPE and STAAD.Pro: Anchors
Hello Dana, Under AutoPIPE Tools> Model Options> Edit> See the Settings for "Rigid Stiffness Anchors & Supports". An ANCHOR in AutoPIPE is assume to rigidly restrict movement on 6 axis...
View ArticleWiki Page: 05. Combination Load Cases (Tools> Combinations dialog)
Applies To Product(s): AutoPIPE, Version(s): 2004, XM, & V8i Environment: N/A Area: Load Cases Subarea: Original Author: Bentley Technical Support Group Load Combinations To review, modify or print...
View ArticleWiki Page: "Non-Code Comb." tab questions in AutoPIPE
Applies To Product(s): AutoPIPE, Version(s): 2004, XM, & V8i Environment: N/A Area: combinations Subarea: Original Author: Bentley Technical Support Group Comments, Questions, and Answers about...
View ArticleWiki Page: Results and Graphs in PULS
Applies To Product(s): AutoPIPE, Version(s): 2004, XM, & V8i Environment: N/A Area: Results Subarea: Original Author: Bentley Technical Support Group Comments, Questions, and Answers about results...
View ArticleWiki Page: 05. FAQ about AutoPIPE's ATS
Applies To Product(s): AutoPIPE, Version(s): 2004, XM, & V8i Environment: N/A Area: ATS Subarea: Original Author: Bentley Technical Support Group Item #1: I am trying to locate the reference...
View ArticleWiki Page: Calculations in PULS
Applies To Product(s): AutoPIPE, Version(s): 2004, XM, & V8i Environment: N/A Area: Calculations Subarea: Original Author: Bentley Technical Support Group Comments, Questions, and Answers about...
View ArticleWiki Page: 04j. Model Flow (Oscillating) Vibration - AutoPIPE
Applies To Product(s): AutoPIPE Version(s): 2004, XM, V8i Environment: N/A Area: Subarea: Original Author: Bentley Technical Support Group Date Logged & Current Version Aug. 2015 09.06.02.06...
View ArticleWiki Page: Modeling Approaches in AutoPIPE
Applies To Product(s): AutoPIPE, Version(s): 2004, XM, & V8i Environment: N/A Area: Modeling Subarea: Original Author: Bentley Technical Support Group AutoPIPE's help "Modeling Approaches"...
View ArticleForum Post: RE: Integration of AutoPIPE and STAAD.Pro: Anchors
Thank you for your assistance Mike. I have worked around the problem by creating 5 nodes with the spacing of 1mm: - Node 1: Guide - Node 2: Pipe stop - Node 3: X Rotation - Node 4: Y Rotation - Node 5:...
View ArticleForum Post: AutoPIPE and STAAD Integration: Transferring STAAD Loads to AutoPIPE
On a topside or jacket structure, the stiffness of the structure is significantly higher than that of the piping. Hence the effects of piping stiffness is negligible on the outcome of stresses on the...
View ArticleForum Post: Cut Short for expansion loop
Dear All, I want to use the cut short function to minimize expansion loop dimensions on a long run steam pipe (P=47Barg & T=380°C). I am aware that according to ASME B31.1 cut short is not allowed...
View Article